VOLVO
BECM-P0AA100 - Hybrid/EV Battery Positive Contactor Circuit Stuck Closed. General Failure Information. No sub type information
System
Batteristyring (BECM)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
1 modellV60 (2011–)
Vis modeller per årsmodell og motor (2)
Hva betyr feilkoden?
The BECM controls and monitors the contactors of the high voltage battery at the same time. The code is set when voltage is present in circuit A although the positive contactor was told to open, which suggests the contact is welded shut. The fault may be caused by a damaged high voltage battery.
Mulige årsaker
- The high voltage battery is damaged
Hva du kan gjøre
- 1Read and note the fault code, clear it and road test to check whether it returns
- 2Check that the car's ordinary battery is charged and in good condition
- 3Have a workshop with diagnostic equipment check the contactors and the high voltage battery
- 4The high voltage system should only be handled by qualified personnel, so have a workshop carry out all work on the battery and other high voltage parts
Symptomer du kan merke4
- Red warning symbol and message in the display
- Charging of the high voltage battery stops or works poorly
- Drive modes PURE, SAVE and AWD disengage automatically or cannot be selected
- The combustion engine runs more often than normal in HYBRID mode
Hva feilen kan påvirke2
- The high voltage battery cannot be charged
- Electric propulsion is not possible
Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.