BECM-P0C7800 - Battery Charger Hybrid/EV System Precharge Time Too Long. General Failure Information. No sub type information
System
Batteristyring (BECM)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
1 modellV60 (2011–)
Vis modeller per årsmodell og motor (2)
Hva betyr feilkoden?
Once the contactors close, voltage in the HV system should climb. The code is set when that climb in circuit A is too slow, which may be caused by an open circuit in the high voltage cable in the circuit.
Mulige årsaker
- The high voltage cable in the circuit has an open circuit
Hva du kan gjøre
- 1Read and note the fault code, clear it and road test to check whether it returns
- 2Have a workshop check visible damage to the high voltage cable sheathing, such as chafing or pinch marks
- 3Have a workshop check the high voltage cable in the circuit for an open circuit
- 4The high voltage system should only be handled by qualified personnel, so have a workshop carry out all work on the battery and other high voltage parts
Symptomer du kan merke4
- Yellow warning symbol and message in the display
- Charging of the high voltage battery stops or works poorly, especially while driving
- Drive modes PURE, SAVE and AWD disengage automatically or cannot be selected
- Low voltage in the battery or a dead battery
Hva feilen kan påvirke3
- Charging with the combustion engine is not possible
- Charging through brake energy recovery is not possible
- Electric propulsion is not possible
Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.