CEM-B10C011 - Fuel Pump Power Supply. General Electrical Failures. Circuit short to ground
System
Sentral elektronikk (CEM)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
2 modellerV40 (2013–), V40 Cross Country (2013–)
Vis modeller per årsmodell og motor (2)
Hva betyr feilkoden?
The central electronic module (CEM) controls the voltage supply to the fuel pump and monitors the voltage on the cable. The code is stored when the module detects that the supply cable to the pump is short-circuited to ground. The fuel pump may then lack voltage, and the engine does not start, either sometimes or always.
Mulige årsaker
- The fuel pump supply cable is short-circuited to ground
Hva du kan gjøre
- 1Check that the relevant fuses are intact, especially the one for the fuel pump. Their locations are in the owner's manual or on the fuse box cover
- 2Switch the ignition on and listen for a short hum from the tank when the pump should start
- 3Use a multimeter to check that the supply cable to the fuel pump has no contact with ground (the body)
- 4If you have a diagnostic tool: activate the fuel pump and listen for it to start
- 5If the fault returns, have a workshop with diagnostic equipment check the wiring between the control module and the fuel pump
Symptomer du kan merke1
- Engine does not start, either sometimes or always
Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.