VOLVO
CRM-2061 - Position encoder 2, rear roof. Shorted to supply
System
Chassis (Bremser, styring, fjæring)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
1 modellC70 (2006–2013)
Vis modeller per årsmodell og motor (1)
Hva betyr feilkoden?
Position sensor 2 in the rear roof section puts voltage on its signal wire at the same moment the control module is to activate it. The fault is caused by the signal wire being short-circuited to battery voltage. The roof may then be operated only in a limited way or not at all.
Mulige årsaker
- Signal wire short-circuited to battery voltage
Hva du kan gjøre
- 1With the ignition off, look for damage to the signal wire to position sensor 2 in the rear roof section: chafing, pinching or damaged insulation.
- 2With the ignition off, use a multimeter to check that the signal wire has no battery voltage. Voltage means a short to positive, and the wire must then be repaired or replaced.
- 3If the wire is in good condition, have a workshop replace position sensor 2.
- 4If the fault remains after this, have a workshop check the convertible roof control module, as the fault most likely lies within it.
Symptomer du kan merke1
- No or limited roof operation
Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.