VOLVO
ECM-0019 - Electric cooling fan, full speed. Signal too low. Intermittent fault.
System
Motorstyring (ECM)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
2 modellerS70 (1997–2000), V70 (1997–2000)
Vis modeller per årsmodell og motor (2)
Hva betyr feilkoden?
The engine control module has recorded a fault in the control signal to the electric cooling fan at full speed, for example a signal that is too low or a break. The fault is intermittent, meaning it comes and goes, and may not be present right now. The fan may then run when it should not, or not run at full speed when it is needed.
Mulige årsaker
- The signal is shorted to earth
- Break in the signal wire
- Break in the supply wire to the cooling fan relay
- Contact resistance in the connections
Hva du kan gjøre
- 1Check that the fuse for the electric cooling fan is intact. Its location is in the owner's manual or the fuse list
- 2Check the connectors to the cooling fan relay and the engine control module for poor contact and oxidation
- 3Check the wires to the fan for chafing and pinch damage
- 4Measure with a multimeter that the signal wire has no break and is not shorted to earth
- 5Clear the fault code and road test the car. If it returns, have a workshop investigate the circuit and the cooling fan relay
Symptomer du kan merke2
- The electric cooling fan runs all the time, even with the ignition off
- The electric cooling fan does not run at full speed
Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.