VOLVO
ECM-1800 - Swirl actuator control. Signal too high
System
Motorstyring (ECM)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
8 modellerC30 (2007–2013), C70 (2006–2013), S40 (2004–2013), S60 (2001–2009), V50 (2004–2013), V70 (2000–2008), V70 XC / XC70 (2001–2007), XC90 (2003–)
Vis modeller per årsmodell og motor (20)
- Volvo C30 (2007–2013)2007Kun motor: D5244T8, D5244T9
- Volvo C30 (2007–2013)2008–2010Kun motor: D5244T13, D5244T8, D5244T9
- Volvo C70 (2006–2013)2007Kun motor: D5244T8, D5244T9
- Volvo C70 (2006–2013)2008–2010Kun motor: D5244T13, D5244T8, D5244T9
- Volvo S40 (2004–2013)2006Kun motor: D5244T8
- Volvo S40 (2004–2013)2007Kun motor: D5244T8, D5244T9
- Volvo S40 (2004–2013)2008–2010Kun motor: D5244T13, D5244T8, D5244T9
- Volvo S60 (2001–2009)2006Kun motor: D5244T4, D5244T5, D5244T6, D5244T7
- Volvo S60 (2001–2009)2007–2009Kun motor: D5244T4, D5244T5, D5244T7
- Volvo V50 (2004–2013)2006Kun motor: D5244T8
- Volvo V50 (2004–2013)2007Kun motor: D5244T8, D5244T9
- Volvo V50 (2004–2013)2008–2010Kun motor: D5244T13, D5244T8, D5244T9
- Volvo V70 (2000–2008)2006Kun motor: D5244T4, D5244T5, D5244T6, D5244T7
- Volvo V70 (2000–2008)2007Kun motor: D5244T4, D5244T5, D5244T7
- Volvo V70 (2000–2008)2008Kun motor: D5244T5, D5244T7
- Volvo V70 XC / XC70 (2001–2007)2006–2007Kun motor: D5244T4
- Volvo XC90 (2003–)2006–2007Kun motor: D5244T4
- Volvo XC90 (2003–)2008–2010Kun motor: D5244T4, D5244T5
- Volvo XC90 (2003–)2011Kun motor: D5244T18, D5244T4, D5244T5
- Volvo XC90 (2003–)2012Alle motorer unntatt: B5254T2, B6324S5
Hva betyr feilkoden?
The ECM checks the signal to the swirl flap motor, which operates the swirl flaps in the intake duct. If the signal is too high, fault code ECM-1800 is set.
Mulige årsaker
- Signal wire short-circuited to voltage
- Damaged linkage between the swirl flap motor and the swirl duct
- Damaged swirl flap motor
Hva du kan gjøre
- 1Switch off the ignition and look for chafed or pinched wires to the swirl flap motor. Then use a multimeter to check that the signal wire is not shorted to battery voltage
- 2Check that the linkage between the swirl flap motor and the swirl duct is firmly attached and undamaged
- 3If you have a diagnostic tool: activate the swirl flap motor and listen for a ticking sound while it works
- 4If the fault remains, have a workshop check or replace the swirl flap motor
Symptomer du kan merke2
- Poor acceleration
- The engine feels lacking in power
Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.