Hopp til innhold
    OBD Tuning
    SEND TIL OSS
    SEND TIL OSS
    Hjem
    Feilkoder
    VOLVO
    ECM-650C
    VOLVO

    ECM-650C - Engine cooling fan (FC). Signal too high

    System

    Motorstyring (ECM)

    Volvo-modeller feilkoden gjelder for

    Gjelder følgende modeller:

    5 modeller

    S60 (2001–2009), S80 (1999–2006), V70 (2000–2008), V70 XC / XC70 (2001–2007), XC90 (2003–)

    Vis modeller per årsmodell og motor (14)
    • Volvo S60 (2001–2009)2005–2006Kun motor: B5204T5, B5244T4, B5244T5, B5254T2, B5254T4
    • Volvo S60 (2001–2009)2007Kun motor: B5204T5, B5244T5, B5254T2, B5254T4
    • Volvo S60 (2001–2009)2008–2009Kun motor: B5204T5, B5244T5, B5254T2
    • Volvo S80 (1999–2006)2005–2006Kun motor: B5204T5, B5244T4, B5254T2, B6294S2, B6294T
    • Volvo V70 (2000–2008)2005Kun motor: B5204T5, B5244T4, B5244T5, B5254T2, B5254T4
    • Volvo V70 (2000–2008)2006–2007Kun motor: B5204T5, B5244T5, B5254T2, B5254T4
    • Volvo V70 (2000–2008)2008Kun motor: B5254T2
    • Volvo V70 XC / XC70 (2001–2007)2005Alle motorer unntatt: D5244T
    • Volvo V70 XC / XC70 (2001–2007)2006Kun motor: B5244T4, B5254T2
    • Volvo V70 XC / XC70 (2001–2007)2007Kun motor: B5254T2
    • Volvo XC90 (2003–)2005–2006Kun motor: B5254T2, B6294T
    • Volvo XC90 (2003–)2007–2012Kun motor: B5254T2
    • Volvo XC90 (2003–)2013–2014Kun motor: B5254T9
    • Volvo XC90 (2003–)2015

    Hva betyr feilkoden?

    The engine control module checks the signal wire to the electric cooling fan and stores the fault code when the signal is too high. The fan may keep running for a while after the engine is switched off, and the length of that run-on depends on engine temperature, the temperature in the engine bay and the A/C system pressure.

    Mulige årsaker

    • Signal wire shorted to supply voltage
    • Damaged electric cooling fan

    Hva du kan gjøre

    1. 1With the ignition off, check that the fan blades turn freely and nothing is blocking them
    2. 2With the ignition on, check that the electric cooling fan works at all its speed steps
    3. 3Use a multimeter to check whether the signal wire between the engine control module and the fan control module is shorted to supply voltage
    4. 4Check the fuse and ground lead to the electric cooling fan. The fuse box shows where the fuse is
    5. 5Replace the fan control module if it cannot be activated at any speed and there are no faults in the wiring

    Symptomer du kan merke1

    • The cooling fan keeps running even with the ignition off

    Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.

    OBD Tuning

    Sveriges ledende ekspertsenter for bilelektronikk. Vi tilbyr profesjonell ECU-tuning, reparasjon av styreenheter og diagnostikk med 12 måneders garanti.

    Tjenester

    • Motoroptimalisering
    • ECU Reparasjon
    • Modulkloning
    • Instrumentpanel
    • SRS / Airbag
    • Startsperre

    Database & Diagnostikk

    • ECU-database
    • DTC Feilkodekatalog
    • Diagnoseguider & Måleverdier
    • AI Feilkodeanalysator
    • Nyheter

    ECU-produsenter

    • Bosch
    • Continental
    • Delphi
    • Delco
    • Denso
    • Magneti Marelli
    • Siemens / VDO
    • Keihin
    • Temic

    Selskap

    • Om oss
    • Kontakt
    • Verkstedpartnere
    • Fraktguide
    • Garanti
    • FAQ
    • Vilkår
    • Personvern
    • Nettstedskart

    • Motoroptimalisering
    • ECU Reparasjon
    • Modulkloning
    • Instrumentpanel
    • SRS / Airbag
    • Startsperre

    • ECU-database
    • DTC Feilkodekatalog
    • Diagnoseguider & Måleverdier
    • AI Feilkodeanalysator
    • Nyheter

    • Bosch
    • Continental
    • Delphi
    • Delco
    • Denso
    • Magneti Marelli
    • Siemens / VDO
    • Keihin
    • Temic

    • Om oss
    • Kontakt
    • Verkstedpartnere
    • Fraktguide
    • Garanti
    • FAQ
    • Vilkår
    • Personvern
    • Nettstedskart

    Besøk oss

    Gjuterigatan 29, Karlstad

    Ring oss

    054-830 480

    E-post oss

    service@obdtuning.se

    © 2026 OBD Tuning Karlstad. Alle rettigheter forbeholdt.