    ECM-650D
    VOLVO

    ECM-650D - Engine cooling fan (FC). Signal too low

    System

    Motorstyring (ECM)

    Volvo-modeller feilkoden gjelder for

    Gjelder følgende modeller:

    5 modeller

    S60 (2001–2009), S80 (1999–2006), V70 (2000–2008), V70 XC / XC70 (2001–2007), XC90 (2003–)

    Vis modeller per årsmodell og motor (14)
    • Volvo S60 (2001–2009)2005–2006Kun motor: B5204T5, B5244T4, B5244T5, B5254T2, B5254T4
    • Volvo S60 (2001–2009)2007Kun motor: B5204T5, B5244T5, B5254T2, B5254T4
    • Volvo S60 (2001–2009)2008–2009Kun motor: B5204T5, B5244T5, B5254T2
    • Volvo S80 (1999–2006)2005–2006Kun motor: B5204T5, B5244T4, B5254T2, B6294S2, B6294T
    • Volvo V70 (2000–2008)2005Kun motor: B5204T5, B5244T4, B5244T5, B5254T2, B5254T4
    • Volvo V70 (2000–2008)2006–2007Kun motor: B5204T5, B5244T5, B5254T2, B5254T4
    • Volvo V70 (2000–2008)2008Kun motor: B5254T2
    • Volvo V70 XC / XC70 (2001–2007)2005Alle motorer unntatt: D5244T
    • Volvo V70 XC / XC70 (2001–2007)2006Kun motor: B5244T4, B5254T2
    • Volvo V70 XC / XC70 (2001–2007)2007Kun motor: B5254T2
    • Volvo XC90 (2003–)2005–2006Kun motor: B5254T2, B6294T
    • Volvo XC90 (2003–)2007–2012Kun motor: B5254T2
    • Volvo XC90 (2003–)2013–2014Kun motor: B5254T9
    • Volvo XC90 (2003–)2015

    Hva betyr feilkoden?

    The fault code is set when the engine control module detects a signal that is too low on the wire to the electric cooling fan. After the engine is switched off the fan may run for a while, and how long depends on engine temperature, the temperature in the engine bay and the A/C system pressure.

    Mulige årsaker

    • Short circuit to supply voltage in the signal cable
    • The electric cooling fan is damaged

    Hva du kan gjøre

    1. 1With the ignition off, check that the fan blades move freely and are not blocked
    2. 2Run the electric cooling fan through each speed step with the diagnostic tool and listen for it to start
    3. 3Use a multimeter to check that the signal wire between the engine control module and the fan control module has no open circuit or damage
    4. 4A blown fuse in the supply to the electric cooling fan means no current, so check that first
    5. 5Replace the fan control module if it cannot be activated at any speed and the wiring is intact

    Symptomer du kan merke1

    • The electric cooling fan does not work

    Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.

    OBD Tuning

    Sveriges ledende ekspertsenter for bilelektronikk. Vi tilbyr profesjonell ECU-tuning, reparasjon av styreenheter og diagnostikk med 12 måneders garanti.

    Tjenester

    • Motoroptimalisering
    • ECU Reparasjon
    • Modulkloning
    • Instrumentpanel
    • SRS / Airbag
    • Startsperre

    Database & Diagnostikk

    • ECU-database
    • DTC Feilkodekatalog
    • Diagnoseguider & Måleverdier
    • AI Feilkodeanalysator
    • Nyheter

    ECU-produsenter

    • Bosch
    • Continental
    • Delphi
    • Delco
    • Denso
    • Magneti Marelli
    • Siemens / VDO
    • Keihin
    • Temic

    Selskap

    • Om oss
    • Kontakt
    • Verkstedpartnere
    • Fraktguide
    • Garanti
    • FAQ
    • Vilkår
    • Personvern
    • Nettstedskart

    • Motoroptimalisering
    • ECU Reparasjon
    • Modulkloning
    • Instrumentpanel
    • SRS / Airbag
    • Startsperre

    • ECU-database
    • DTC Feilkodekatalog
    • Diagnoseguider & Måleverdier
    • AI Feilkodeanalysator
    • Nyheter

    • Bosch
    • Continental
    • Delphi
    • Delco
    • Denso
    • Magneti Marelli
    • Siemens / VDO
    • Keihin
    • Temic

    • Om oss
    • Kontakt
    • Verkstedpartnere
    • Fraktguide
    • Garanti
    • FAQ
    • Vilkår
    • Personvern
    • Nettstedskart

    Besøk oss

    Gjuterigatan 29, Karlstad

    Ring oss

    054-830 480

    E-post oss

    service@obdtuning.se

    © 2026 OBD Tuning Karlstad. Alle rettigheter forbeholdt.