VOLVO
ECM-810F - Starter relay 1. Electrical fault
System
Motorstyring (ECM)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
3 modellerC30 (2007–2013), S40 (2004–2013), V50 (2004–2013)
Vis modeller per årsmodell og motor (3)
Hva betyr feilkoden?
Starter motor relay 1 has an electrical fault: its connections may be broken or shorted to ground, or the relay may be stuck in the open position. The voltage to the starter motor is then not supplied, and automatic engine start and stop is switched off. The fault applies to the C30, S40 (04-) and V50.
Mulige årsaker
- Open circuit on the connections
- Short circuit to ground
- Starter motor relay 1 is stuck in the open position
- Damaged starter motor relay 1
Hva du kan gjøre
- 1Check that the fuses are intact
- 2Check that the wiring to starter motor relay 1 is not broken or shorted to ground, preferably with a multimeter
- 3Try a start attempt and note whether the starter motor turns and whether the relay gives a click
- 4If you have a diagnostic tool: activate starter motor relay 1 and check whether the starter then turns
- 5If the fault remains, have a workshop replace starter motor relay 1 if it is damaged, once the connections have been checked
Symptomer du kan merke3
- Automatic engine start and stop does not work
- The engine does not start and the starter motor does not turn
- A clicking sound is heard at start attempts
Hva feilen kan påvirke1
- The automatic engine start and stop function is switched off
Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.