VOLVO
ECM-P036815 - Camshaft Position Sensor B Circuit High (Bank 1). General Electrical Failures. Circuit short to battery or open
System
Motorstyring (ECM)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
7 modellerS60 (2011–), S80 (2007–), V40 (2013–), V40 Cross Country (2013–), V60 (2011–), V70 (2008–), XC60 (2009–)
Vis modeller per årsmodell og motor (20)
- Volvo S60 (2011–)2011Kun motor: B4164T, B4164T3, B4204T6, B4204T7
- Volvo S60 (2011–)2012–2014Kun motor: B4164T, B4164T2, B4164T3, B4204T7
- Volvo S60 (2011–)2015Kun motor: B4164T, B4164T2, B4164T3
- Volvo S80 (2007–)2010Kun motor: B4204T6
- Volvo S80 (2007–)2011Kun motor: B4164T, B4204T6, B4204T7
- Volvo S80 (2007–)2012–2014Kun motor: B4164T, B4164T2, B4204T6, B4204T7
- Volvo S80 (2007–)2015Kun motor: B4164T
- Volvo V40 (2013–)2013Kun motor: B4164T, B4164T3
- Volvo V40 (2013–)2014–2015Kun motor: B4164T, B4164T3, B4164T4
- Volvo V40 Cross Country (2013–)2013–2015Kun motor: B4164T
- Volvo V60 (2011–)2011Kun motor: B4164T, B4164T3, B4204T6, B4204T7
- Volvo V60 (2011–)2012–2014Kun motor: B4164T, B4164T2, B4164T3, B4204T7
- Volvo V60 (2011–)2015Kun motor: B4164T, B4164T2, B4164T3
- Volvo V70 (2008–)2010Kun motor: B4204T6
- Volvo V70 (2008–)2011Kun motor: B4164T, B4204T6, B4204T7
- Volvo V70 (2008–)2012–2014Kun motor: B4164T, B4164T2, B4204T7
- Volvo V70 (2008–)2015Kun motor: B4164T, B4164T2
- Volvo XC60 (2009–)2010Kun motor: B4204T6
- Volvo XC60 (2009–)2011–2012Kun motor: B4204T6, B4204T7
- Volvo XC60 (2009–)2013–2015Kun motor: B4204T7
Hva betyr feilkoden?
The code applies to the exhaust camshaft sensor on bank 1, where the signal is constantly high. It can come from a short circuit to supply voltage or from an open circuit in the wiring.
Mulige årsaker
- Open circuit in the signal wire
- Signal wire short circuit to supply voltage
- Supply wire short circuit to ground
- Open circuit in the ground lead
- Damaged camshaft sensor
Hva du kan gjøre
- 1If you have a diagnostic tool, start the engine and read the fault status. 'Fault found' means the fault is permanent.
- 2Check that the fuses are intact.
- 3With the ignition off, check the connector at the exhaust camshaft sensor on bank 1 for contact resistance and oxidation.
- 4Use a multimeter to check that the signal wire is continuous and has no contact with supply voltage.
- 5Use a multimeter to check that the ground lead has no open circuit and that the supply wire is not shorted to ground.
- 6Check that the exhaust camshaft sensor is firmly fixed in its position.
Symptomer du kan merke2
- Engine does not start, sometimes or every time
- Engine is hard to start and cranks slowly