VOLVO
ECM-P05621C - System Voltage Low. General Electrical Failures. Circuit voltage out of range
System
Motorstyring (ECM)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
7 modellerS60 (2011–), S80 (2007–), V40 (2013–), V40 Cross Country (2013–), V60 (2011–), V70 (2008–), XC60 (2009–)
Vis modeller per årsmodell og motor (20)
- Volvo S60 (2011–)2011Kun motor: B4164T, B4164T3, B4204T6, B4204T7
- Volvo S60 (2011–)2012–2014Kun motor: B4164T, B4164T2, B4164T3, B4204T7
- Volvo S60 (2011–)2015Kun motor: B4164T, B4164T2, B4164T3
- Volvo S80 (2007–)2010Kun motor: B4204T6
- Volvo S80 (2007–)2011Kun motor: B4164T, B4204T6, B4204T7
- Volvo S80 (2007–)2012–2014Kun motor: B4164T, B4164T2, B4204T6, B4204T7
- Volvo S80 (2007–)2015Kun motor: B4164T
- Volvo V40 (2013–)2013Kun motor: B4164T, B4164T3
- Volvo V40 (2013–)2014–2015Kun motor: B4164T, B4164T3, B4164T4
- Volvo V40 Cross Country (2013–)2013–2015Kun motor: B4164T
- Volvo V60 (2011–)2011Kun motor: B4164T, B4164T3, B4204T6, B4204T7
- Volvo V60 (2011–)2012–2014Kun motor: B4164T, B4164T2, B4164T3, B4204T7
- Volvo V60 (2011–)2015Kun motor: B4164T, B4164T2, B4164T3
- Volvo V70 (2008–)2010Kun motor: B4204T6
- Volvo V70 (2008–)2011Kun motor: B4164T, B4204T6, B4204T7
- Volvo V70 (2008–)2012–2014Kun motor: B4164T, B4164T2, B4204T7
- Volvo V70 (2008–)2015Kun motor: B4164T, B4164T2
- Volvo XC60 (2009–)2010Kun motor: B4204T6
- Volvo XC60 (2009–)2011–2012Kun motor: B4204T6, B4204T7
- Volvo XC60 (2009–)2013–2015Kun motor: B4204T7
Hva betyr feilkoden?
The ECM monitors the system voltage and sets the code when the voltage is wrongly low. The causes can lie in the generator, the charging system or the battery, but also in contact resistance in connectors and connections.
Mulige årsaker
- Problem with the generator
- Faulty charging system
- Damaged battery
- Contact resistance or oxidation in connectors and connections
Hva du kan gjøre
- 1Check that the fuses are intact
- 2Check the battery terminals and connections for contact resistance and oxidation
- 3Check the other connectors and connections in the charging circuit for looseness and oxidation
- 4If you have diagnostic equipment: read the system voltage in live data with the engine running and compare it with the value when the engine is stopped
- 5If the connections are clean and tight, have a workshop check the generator and battery
Symptomer du kan merke2
- The engine is hard to start and the starter motor cranks slowly, hard to tell when it happens
- The engine does not start, hard to tell when it happens