VOLVO
ECM-P200835 - Intake Manifold Runner Control Circuit / Open (Bank 1). FM (Frequency Modulated) / PWM (Pulse Width Modulated) Failures. Signal high time above maximum
System
Motorstyring (ECM)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
5 modellerS80 (2007–), V70 (2008–), XC60 (2009–), XC70 (2008–), XC90 (2003–)
Vis modeller per årsmodell og motor (6)
- Volvo S80 (2007–)2007–2009Kun motor: D5244T4, D5244T5
- Volvo V70 (2008–)2008–2009Kun motor: D5244T4, D5244T5
- Volvo XC60 (2009–)2009Alle motorer unntatt: B6304T2
- Volvo XC70 (2008–)2008Alle motorer unntatt: B6324S
- Volvo XC70 (2008–)2009Kun motor: D5244T4, D5244T5
- Volvo XC90 (2003–)2013–2014Kun motor: D5244T18, D5244T5
Hva betyr feilkoden?
Although the code is named pulse width high above maximum, it applies when the swirl damper position differs from the calculated position. The engine control module (ECM) compares the damper position with a calculated value and sets the code when the position is incorrect. The cause may lie in the swirl damper, its linkage or its motor.
Mulige årsaker
- Linkage or swirl damper sticking
- Damaged linkage between the swirl throttle motor and the swirl throttle duct
- Swirl damper motor sticking
- Damaged swirl throttle motor
Hva du kan gjøre
- 1If you have a diagnostic tool: command the swirl damper motor and check that it moves smoothly without sticking
- 2Check that the linkage between the motor and the swirl channel is intact and that nothing is sticking there
- 3Check that the swirl damper motor itself is not damaged or sticking
- 4If the fault remains, have a workshop check the swirl damper motor with diagnostic equipment
Symptomer du kan merke1
- No noticeable symptoms for the driver
Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.