OBC-P0D9815 - Battery Charger Coupler Unlock Control Circuit Performance. General Electrical Failures. Circuit short to battery or open
System
Innebygd lader (OBC)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
1 modellV60 (2011–)
Vis modeller per årsmodell og motor (2)
Hva betyr feilkoden?
The battery charger control module (OBC) checks that the cable can be latched to the car by the lock motor inside the charging socket. The fault is set when the activation signal to the lock motor is overloaded. Charging the high voltage battery is not possible while the fault remains.
Mulige årsaker
- Overload on the signal to the lock motor
Hva du kan gjøre
- 1Read out and erase the fault code, charge again and see whether it comes back
- 2Check that the charging socket in the car is not damaged and that the charging cable can be locked into it without anything blocking it
- 3Have a workshop check the cables to the charging socket. Do not work on the high voltage system yourself
Symptomer du kan merke3
- Charging the high voltage battery from an external charging cable does not happen, is reduced or does not work correctly
- The LED on the charging cable or the charging socket shows a fault and charging is reduced
- The lock function in the charging socket does not lock or unlock the charging cable
Hva feilen kan påvirke1
- Charging the high voltage battery is not possible