VOLVO
OBC-P0D9916 - Battery Charger Coupler Temperature Sensor Circuit. General Electrical Failures. Circuit voltage below threshold
System
Innebygd lader (OBC)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
1 modellV60 (2011–)
Vis modeller per årsmodell og motor (2)
Hva betyr feilkoden?
The battery charger control module (OBC) checks that the temperature reading from the charging socket is right. The fault is set when the sensor reads too low a signal. The fault can come from a damaged sensor in the charging socket or from damage to gateway OBC or its connection, and then charging the high voltage battery is not possible.
Mulige årsaker
- The sensor reading the charging socket temperature is damaged
- Defective connection to gateway OBC
- Gateway OBC is damaged
Hva du kan gjøre
- 1Read out and erase the fault code, charge again and see whether it comes back
- 2Have a workshop check that the charging socket in the car is not damaged and that the cable is fully seated in it
- 3Have a workshop check the cables and gateway OBC. Do not work on the high voltage system yourself
Symptomer du kan merke2
- Charging the high voltage battery from an external charging cable does not happen, is reduced or does not work correctly
- The LED on the charging cable or the charging socket shows a fault and charging is reduced
Hva feilen kan påvirke1
- Charging the high voltage battery is not possible
Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.