OBC-U100800 - Private Communication Network Bus (-) shorted to Bus (+). General Failure Information. No sub type information
System
Innebygd lader (OBC)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
1 modellV60 (2011–)
Vis modeller per årsmodell og motor (2)
Hva betyr feilkoden?
The battery charger control module (OBC) has registered a short circuit in the internal communication network between itself and the charger, which sits in the same unit. The fault is set when the cable is plugged in and its switch is turned on. The fault is caused by an internal fault in OBC, so charging the high voltage battery is not possible while it remains.
Mulige årsaker
- Internal fault in the battery charger OBC
Hva du kan gjøre
- 1Read out and erase the fault code, charge again with the charging cable connected and see whether it comes back
- 2Have a workshop check that the fuses that belong to the charging system are intact
- 3As it is an internal fault in the charger, have a workshop check the control module. Do not work on the high voltage system yourself
Symptomer du kan merke2
- Charging the high voltage battery from an external charging cable does not happen, is reduced or does not work correctly
- The LED on the charging cable or the charging socket shows a fault and charging is reduced
Hva feilen kan påvirke1
- Charging the high voltage battery is not possible
Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.