PSR-0007 - M1, M2, M3, M4 or MC. Shorted to supply
System
Drivlinje (Motor og girkasse)
Volvo-modeller feilkoden gjelder for
Gjelder følgende modeller:
3 modellerC30 (2007–2013), C30 Electric (2011–2013), C70 (2006–2013)
Vis modeller per årsmodell og motor (3)
Hva betyr feilkoden?
The right power seat control module (PSR) registers too high a voltage on one of the signal wires to the seat motors. This means that wire is touching a live supply instead of being insulated, and the automatic adjustments can stop working as a result.
Mulige årsaker
- One of the signal wires to the seat motors is shorted to voltage
Hva du kan gjøre
- 1With the battery negative lead disconnected, use a multimeter to check that the signal wires to the seat motors are not in contact with voltage
- 2Look for chafing, pinched areas or melted insulation on the wires to the seat motors and repair them
- 3Check that the connectors to the seat motors are firmly fitted and undamaged
- 4If the wires are intact, have a workshop check the seat motors and the seat control module
Symptomer du kan merke1
- Automatic adjustment of the seat and outer mirror does not work
Generell veiledning for bileiere. Feilsøking på bilen kan peke på en annen årsak.