AEM-4F61
VOLVO
AEM-4F61 - Back-up (reversing) warning system. Signal too high. Permanent fault
System
Zubehörmodul (AEM)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
4 ModelleS60 (2001–2009), S80 (1999–2006), V70 (2000–2008), V70 XC / XC70 (2001–2007)
Modelle nach Baujahr und Motor anzeigen (4)
Was bedeutet der Fehlercode?
The AEM has registered a signal that is too high on the supply to the reversing warning system while reverse gear is not selected. The fault is permanent and the reversing warning is switched off. The cause is usually a short to supply voltage in the supply wire or a faulty warning unit.
Mögliche Ursachen
- Supply wire to the reversing warning system shorted to supply voltage
- Faulty reversing warning system
Was Sie tun können
- 1Follow the supply wire to the reversing warning system and look for chafing or damage
- 2Check the connectors at the reversing warning system for oxidation and damage
- 3Check that the reversing warning works when reverse gear is selected
- 4If the fault remains, have a workshop check the warning system after the wiring has been checked
Symptome, die Sie bemerken können1
- Reversing warning system does not work
Was der Fehler beeinflussen kann1
- The reversing warning system is switched off
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.