CPM-3541
VOLVO
CPM-3541 - Flame sensor. Signal too high / Signal missing
System
Verbrennungsheizung (CPM)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
5 ModelleC30 (2007–2013), C30 Electric (2011–2013), C70 (2006–2013), S40 (2004–2013), V50 (2004–2013)
Modelle nach Baujahr und Motor anzeigen (5)
Was bedeutet der Fehlercode?
The combustion preheater module (CPM) has registered a signal from the flame sensor that is too high. The cause may be a short to supply voltage in the cable, poor contact or a damaged flame sensor. The heater cannot be activated until the code has been cleared.
Mögliche Ursachen
- The cable between the CPM and the flame sensor is shorted to supply voltage
- Contact resistance, oxidation or loose connections
- Damaged flame sensor
Was Sie tun können
- 1Clear the code and check that it does not return when the heater starts
- 2If you have a diagnostic tool, read whether a flame was detected after a completed heater run and compare it with what the heater did
- 3Disconnect the connector at the flame sensor and check that the contacts are secure and free from oxidation
- 4Use a multimeter to check that the cable from the connector to the flame sensor carries no voltage when the heater is off; if it does, the cable is shorted to positive
- 5If the fault returns, have a workshop check the flame sensor and the wiring to the CPM
Symptome, die Sie bemerken können2
- Poor heating in the passenger compartment
- The parking heater does not work
Was der Fehler beeinflussen kann1
- The heater cannot be activated until the fault code has been cleared
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.