CRM-2082
VOLVO
CRM-2082 - Hall sensor 11. Short to GND, disconnected or internal error
System
Fahrwerk (Bremsen, Lenkung, Federung)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
1 ModellC70 (2006–2013)
Modelle nach Baujahr und Motor anzeigen (1)
Was bedeutet der Fehlercode?
Hall sensor 11 in the convertible roof gives no pulse when the hydraulic pump is running, and its power consumption is above normal. The fault may be a signal wire short-circuited to ground, a broken connection, or an internal fault in the sensor or the control module. The roof may then be operated only in a limited way or not at all.
Mögliche Ursachen
- Signal wire short-circuited to ground
- Broken connection between hall sensor 11 and the roof control module
- Internal fault in hall sensor 11
- Internal fault in the convertible roof control module
Was Sie tun können
- 1With the ignition off, check the connectors at hall sensor 11 and at the control module for corrosion, looseness and loose contacts.
- 2Use a multimeter to check that the wire from hall sensor 11 has continuity to the control module and is not grounded.
- 3Repair or replace the wire if it is broken or grounded. If the wire is intact, have a workshop replace hall sensor 11.
- 4If the fault remains after this, have a workshop check the convertible roof control module.
Symptome, die Sie bemerken können2
- No or limited roof operation
- A message on the text display
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.