ECM-0352 - Ignition coil cyl 2.Signal too low
System
Motorsteuergerät (ECM)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
3 ModelleC30 (2007–2013), S40 (2004–2013), V50 (2004–2013)
Modelle nach Baujahr und Motor anzeigen (13)
- Volvo C30 (2007–2013)2007–2009Nur Motor: B4184S11, B4184S8, B4204S3
- Volvo C30 (2007–2013)2010Nur Motor: B4184S11, B4184S8, B4204S3, B4204S4
- Volvo C30 (2007–2013)2011–2013Nur Motor: B4204S3, B4204S4
- Volvo S40 (2004–2013)2005Nur Motor: B4184S11
- Volvo S40 (2004–2013)2006Nur Motor: B4184S11, B4184S8
- Volvo S40 (2004–2013)2007–2009Nur Motor: B4184S11, B4184S8, B4204S3
- Volvo S40 (2004–2013)2010Nur Motor: B4184S11, B4184S8, B4204S3, B4204S4
- Volvo S40 (2004–2013)2011–2012Nur Motor: B4204S3, B4204S4
- Volvo V50 (2004–2013)2005Nur Motor: B4184S11
- Volvo V50 (2004–2013)2006Nur Motor: B4184S11, B4184S8
- Volvo V50 (2004–2013)2007–2009Nur Motor: B4184S11, B4184S8, B4204S3
- Volvo V50 (2004–2013)2010Nur Motor: B4184S11, B4184S8, B4204S3, B4204S4
- Volvo V50 (2004–2013)2011–2012Nur Motor: B4204S3, B4204S4
Was bedeutet der Fehlercode?
According to the engine control module (ECM), the ignition coil for cylinder 2 gives too short a spark time or too little current, and the fault is set while driving. The cause may be an open or grounded primary lead, an open secondary lead, a damaged ignition coil or a damaged crankshaft pulley.
Mögliche Ursachen
- Open circuit on the ignition coil primary lead
- Short to ground on the ignition coil primary lead
- Open circuit on the ignition coil secondary lead
- Damaged ignition coil
- Damaged pulley on the crankshaft
Was Sie tun können
- 1Read out the fault code, erase it and road-test to see whether it comes back
- 2The ignition system works at high voltage, so keep your hands away from the coil for cylinder 2 and the spark plug leads while the engine runs
- 3Switch off the ignition and unplug the connector to the coil for cylinder 2. Look for loose contacts, corrosion and contact resistance
- 4Check the coil wiring for chafing and breaks, and use a multimeter to confirm the primary lead has no open circuit and is not grounded
- 5Check the crankshaft pulley visually for damaged teeth or other damage
- 6If the fault remains, have a workshop with diagnostic equipment check the ignition coil and its power supply
Symptome, die Sie bemerken können1
- The malfunction indicator lamp (MIL) is on
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.