ECM-180A
VOLVO
ECM-180A - Accelerator pedal (AP) position sensor 1. Faulty power supply
System
Motorsteuergerät (ECM)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
2 ModelleS40 (1996–2004), V40 (1996–2004)
Modelle nach Baujahr und Motor anzeigen (2)
Was bedeutet der Fehlercode?
The accelerator pedal has two sensors. The ECM monitors the power supply to sensor 1, and if that supply is faulty the fault code is set. The engine is then controlled by sensor 2 instead.
Mögliche Ursachen
- Power supply wire short-circuited to system voltage
- Power supply wire short-circuited to ground
- Defective accelerator pedal position sensor
- Defective engine control module
Was Sie tun können
- 1Switch off the ignition and check the accelerator pedal sensor connector for play, contact resistance and oxidation
- 2With a multimeter, check that the supply wire to sensor 1 is not shorted to ground or to system voltage
- 3If you have a diagnostic tool: check in live data that both pedal sensors show reasonable values and track each other as the pedal is pressed
- 4Because the engine is then controlled by only one sensor, have a workshop correct the fault
Symptome, die Sie bemerken können1
- No noticeable symptoms for the driver
Was der Fehler beeinflussen kann1
- The engine is controlled by pedal sensor 2 instead
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.