ECM-1817
VOLVO
ECM-1817 - Engine cooling fan (FC) relay, 1/2 speed. Signal too low
System
Motorsteuergerät (ECM)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
2 ModelleS40 (1996–2004), V40 (1996–2004)
Modelle nach Baujahr und Motor anzeigen (2)
Was bedeutet der Fehlercode?
The cooling fan has half and full speed, and half speed is switched by its own relay, which the engine control module (ECM) monitors. If the control signal to that relay is too low, fault code ECM-1817 is set. Cars without A/C only have half speed.
Mögliche Ursachen
- Control signal wire shorted to ground
- Open circuit in the control signal wire
Was Sie tun können
- 1Switch off the ignition and check the connector to the half-speed cooling fan relay in the engine bay relay box for play and oxidation
- 2With a multimeter, check that the control signal wire to the relay is not broken and not shorted to ground
- 3If you have a diagnostic tool: activate the cooling fan at half speed and check that it starts
- 4If the fault remains, have a workshop replace the half-speed cooling fan relay
Symptome, die Sie bemerken können1
- No noticeable symptoms for the driver
Was der Fehler beeinflussen kann1
- The cooling fan runs at full speed instead of half speed
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.