ECM-1820
VOLVO
ECM-1820 - Swirl actuator control. Faulty signal
System
Motorsteuergerät (ECM)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
8 ModelleC30 (2007–2013), C70 (2006–2013), S40 (2004–2013), S60 (2001–2009), V50 (2004–2013), V70 (2000–2008), V70 XC / XC70 (2001–2007), XC90 (2003–)
Modelle nach Baujahr und Motor anzeigen (20)
- Volvo C30 (2007–2013)2007Nur Motor: D5244T8, D5244T9
- Volvo C30 (2007–2013)2008–2010Nur Motor: D5244T13, D5244T8, D5244T9
- Volvo C70 (2006–2013)2007Nur Motor: D5244T8, D5244T9
- Volvo C70 (2006–2013)2008–2010Nur Motor: D5244T13, D5244T8, D5244T9
- Volvo S40 (2004–2013)2006Nur Motor: D5244T8
- Volvo S40 (2004–2013)2007Nur Motor: D5244T8, D5244T9
- Volvo S40 (2004–2013)2008–2010Nur Motor: D5244T13, D5244T8, D5244T9
- Volvo S60 (2001–2009)2006Nur Motor: D5244T4, D5244T5, D5244T6, D5244T7
- Volvo S60 (2001–2009)2007–2009Nur Motor: D5244T4, D5244T5, D5244T7
- Volvo V50 (2004–2013)2006Nur Motor: D5244T8
- Volvo V50 (2004–2013)2007Nur Motor: D5244T8, D5244T9
- Volvo V50 (2004–2013)2008–2010Nur Motor: D5244T13, D5244T8, D5244T9
- Volvo V70 (2000–2008)2006Nur Motor: D5244T4, D5244T5, D5244T6, D5244T7
- Volvo V70 (2000–2008)2007Nur Motor: D5244T4, D5244T5, D5244T7
- Volvo V70 (2000–2008)2008Nur Motor: D5244T5, D5244T7
- Volvo V70 XC / XC70 (2001–2007)2006–2007Nur Motor: D5244T4
- Volvo XC90 (2003–)2006–2007Nur Motor: D5244T4
- Volvo XC90 (2003–)2008–2010Nur Motor: D5244T4, D5244T5
- Volvo XC90 (2003–)2011Nur Motor: D5244T18, D5244T4, D5244T5
- Volvo XC90 (2003–)2012Alle Motoren außer: B5254T2, B6324S5
Was bedeutet der Fehlercode?
The ECM monitors the signal to the swirl flap motor. If it finds that the signal is faulty, for example because of a break in the wiring, fault code ECM-1820 is set.
Mögliche Ursachen
- Break in the signal wires
Was Sie tun können
- 1Switch off the ignition and check the swirl flap motor connectors for play, contact resistance and oxidation
- 2With a multimeter, check that the signal wires to the swirl flap motor have no break
- 3If you have a diagnostic tool: activate the swirl flap motor. If a ticking sound is heard when it is activated, the motor is working
- 4If the fault remains, have a workshop check the wiring and the swirl flap motor
Symptome, die Sie bemerken können1
- A text message appears in the display
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.