ECM-810F
VOLVO
ECM-810F - Starter relay 1. Electrical fault
System
Motorsteuergerät (ECM)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
3 ModelleC30 (2007–2013), S40 (2004–2013), V50 (2004–2013)
Modelle nach Baujahr und Motor anzeigen (3)
Was bedeutet der Fehlercode?
Starter motor relay 1 has an electrical fault: its connections may be broken or shorted to ground, or the relay may be stuck in the open position. The voltage to the starter motor is then not supplied, and automatic engine start and stop is switched off. The fault applies to the C30, S40 (04-) and V50.
Mögliche Ursachen
- Open circuit on the connections
- Short circuit to ground
- Starter motor relay 1 is stuck in the open position
- Damaged starter motor relay 1
Was Sie tun können
- 1Check that the fuses are intact
- 2Check that the wiring to starter motor relay 1 is not broken or shorted to ground, preferably with a multimeter
- 3Try a start attempt and note whether the starter motor turns and whether the relay gives a click
- 4If you have a diagnostic tool: activate starter motor relay 1 and check whether the starter then turns
- 5If the fault remains, have a workshop replace starter motor relay 1 if it is damaged, once the connections have been checked
Symptome, die Sie bemerken können3
- Automatic engine start and stop does not work
- The engine does not start and the starter motor does not turn
- A clicking sound is heard at start attempts
Was der Fehler beeinflussen kann1
- The automatic engine start and stop function is switched off
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.