ECM-P04804B
VOLVO
ECM-P04804B - Fan 1 Control Circuit. System Internal Failures. Over temperature
System
Motorsteuergerät (ECM)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
7 ModelleS60 (2011–), S80 (2007–), V40 (2013–), V40 Cross Country (2013–), V60 (2011–), V70 (2008–), XC60 (2009–)
Modelle nach Baujahr und Motor anzeigen (20)
- Volvo S60 (2011–)2011Nur Motor: B4164T, B4164T3, B4204T6, B4204T7
- Volvo S60 (2011–)2012–2014Nur Motor: B4164T, B4164T2, B4164T3, B4204T7
- Volvo S60 (2011–)2015Nur Motor: B4164T, B4164T2, B4164T3
- Volvo S80 (2007–)2010Nur Motor: B4204T6
- Volvo S80 (2007–)2011Nur Motor: B4164T, B4204T6, B4204T7
- Volvo S80 (2007–)2012–2014Nur Motor: B4164T, B4164T2, B4204T6, B4204T7
- Volvo S80 (2007–)2015Nur Motor: B4164T
- Volvo V40 (2013–)2013Nur Motor: B4164T, B4164T3
- Volvo V40 (2013–)2014–2015Nur Motor: B4164T, B4164T3, B4164T4
- Volvo V40 Cross Country (2013–)2013–2015Nur Motor: B4164T
- Volvo V60 (2011–)2011Nur Motor: B4164T, B4164T3, B4204T6, B4204T7
- Volvo V60 (2011–)2012–2014Nur Motor: B4164T, B4164T2, B4164T3, B4204T7
- Volvo V60 (2011–)2015Nur Motor: B4164T, B4164T2, B4164T3
- Volvo V70 (2008–)2010Nur Motor: B4204T6
- Volvo V70 (2008–)2011Nur Motor: B4164T, B4204T6, B4204T7
- Volvo V70 (2008–)2012–2014Nur Motor: B4164T, B4164T2, B4204T7
- Volvo V70 (2008–)2015Nur Motor: B4164T, B4164T2
- Volvo XC60 (2009–)2010Nur Motor: B4204T6
- Volvo XC60 (2009–)2011–2012Nur Motor: B4204T6, B4204T7
- Volvo XC60 (2009–)2013–2015Nur Motor: B4204T7
Was bedeutet der Fehlercode?
The code indicates that the electric fan or its control is overheated. The engine control module (ECM) monitors the fan function continuously and tests it while the engine runs. The causes may be that the driver circuit in the engine control module has become too hot, high temperature in the engine bay or a damaged electric fan control module.
Mögliche Ursachen
- The driver circuit in the engine control module overheats because of a low resistance to the battery, but it is not fully short-circuited
- High temperature in the engine bay
- Damaged electric fan control module
Was Sie tun können
- 1With the ignition off, check that nothing blocks the fan blades and that the fan turns freely
- 2Check the fuses for the cooling fan. Their location is given in the owner's manual
- 3If you have a diagnostic tool, read the fault status with the engine running to see whether the fault is active
- 4If the fault returns, have a workshop check the fan control and the electric fan control module
- 5After repair the fault status should show no fault once the diagnosis is complete. Check this with a diagnostic tool
- 6Clear the fault code once the fault has been remedied, and road test
Symptome, die Sie bemerken können1
- The engine may run hot
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.