IAM-4003
VOLVO
IAM-4003 - Microphone input. Signal too high
System
Integriertes Audiomodul (IAM)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
5 ModelleC30 (2007–2013), C30 Electric (2011–2013), C70 (2006–2013), S40 (2004–2013), V50 (2004–2013)
Modelle nach Baujahr und Motor anzeigen (5)
Was bedeutet der Fehlercode?
The integrated audio module (IAM) has detected that the signal from the microphone is too high. The signal wire is short-circuited to voltage, so the signal becomes too strong for the module.
Mögliche Ursachen
- Short circuit to voltage on the signal wire between the module and the microphone
Was Sie tun können
- 1With the ignition off, check the connectors at the microphone and the module for contact resistance, play and oxidation
- 2Go through the wire between the module and the microphone and look for chafing or spots where it may have touched a live wire
- 3Use a multimeter to check that the signal wire has no contact with voltage
- 4After the work, check that the microphone works and that the fault code does not return
Symptome, die Sie bemerken können1
- The microphone does not work