IEM-P16272F
VOLVO
IEM-P16272F - Module Supply Voltage Out Of Range. General Signal Failures. Signal erratic
System
Unbekanntes System / Herstellerspezifisch
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
1 ModellV60 (2011–)
Modelle nach Baujahr und Motor anzeigen (2)
Was bedeutet der Fehlercode?
Although the code is named module supply voltage out of range, it applies when one or more of the control module's internal supply voltages are faulty. The fault is set with the ignition on once the test has started. The causes are a short, break or damage in the supply voltage wiring, a break in the supply from the system relay, or an internal fault in the voltage converter (ISC). Electric propulsion is then not possible.
Mögliche Ursachen
- Supply voltage wiring is short-circuited to ground or supply voltage
- Open circuit in the supply voltage wiring
- Open circuit in the supply from the system relay
- Damaged supply voltage wiring
- Internal fault in the voltage converter (ISC)
Was Sie tun können
- 1Have a workshop check the supply voltage wiring and the supply from the system relay. High voltage systems may only be handled by qualified personnel
- 2If you have a diagnostic tool: read the fault code with the ignition on and see whether it is still there
- 3Do not carry out any work on the control module yourself
- 4After the repair, check that the code is not stored again
Symptome, die Sie bemerken können4
- Text window and warning symbol with a text message
- Drive mode PURE disengages automatically or is unavailable
- Drive mode AWD disengages automatically or is unavailable
- Drive mode HYBRID: the combustion engine runs all the time or too often
Was der Fehler beeinflussen kann2
- Electric propulsion is not possible
- Brake energy regeneration from the electric rear axle is not possible