IGM-C200D84
VOLVO
IGM-C200D84 - Motor Rotation Angle Sensor. Bus Signal / Message Failures. Signal below allowable range
System
Unbekanntes System / Herstellerspezifisch
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
1 ModellV60 (2011–)
Modelle nach Baujahr und Motor anzeigen (2)
Was bedeutet der Fehlercode?
The high voltage generator control module (IGM) monitors the internal components and functions of the starter generator ISG. The code is stored when the speed signal from the ISG indicates that it is rotating backwards, or when the speed is below a limit. The fault is only checked once the combustion engine is running.
Mögliche Ursachen
- Calibration not completed
- Calibration has failed
- Calibration or parameter memory is incorrect, incompatible or not programmed
- The position sensor on the ISG is installed incorrectly
Was Sie tun können
- 1Read out and note the code, clear it and road test with the engine running
- 2Have a workshop check the calibration of the ISG and that the calibration memory is correctly programmed
- 3Have a workshop check that the position sensor on the ISG is fitted correctly
- 4The high voltage system may only be handled by a workshop; do not work on it yourself
Symptome, die Sie bemerken können5
- Warning symbol and text message in the display
- Warning about power supply problems from the alternator and charge regulator
- Charging of the high voltage battery while driving is absent, reduced or not working correctly
- High voltage battery is discharged or charges poorly
- HYBRID drive mode: the combustion engine is active all the time or too often
Was der Fehler beeinflussen kann1
- The high voltage battery cannot be charged by the combustion engine
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.