IGM-P060667
VOLVO
IGM-P060667 - Control module processor. Algorithm Based Failures. Signal incorrect after event
System
Unbekanntes System / Herstellerspezifisch
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
1 ModellV60 (2011–)
Modelle nach Baujahr und Motor anzeigen (2)
Was bedeutet der Fehlercode?
Although the code is named an incorrect signal after an event, it relates to an internal fault in the microprocessor of the high voltage generator control module (IGM). The fault is only checked once the test has started at ignition on, and the code is stored when the conditions are met.
Mögliche Ursachen
- Software fault in the IGM
- Internal fault inside the ISC voltage converter
Was Sie tun können
- 1Read out and clear the code, road test and see whether it returns
- 2Have a workshop check the software in the IGM and download the latest version if needed
- 3The high voltage system may only be handled by a workshop; do not work on it yourself
Symptome, die Sie bemerken können5
- Warning symbol and text message in the display
- Warning about power supply problems from the alternator and charge regulator
- Charging of the high voltage battery while driving is absent, reduced or not working correctly
- High voltage battery is discharged or charges poorly
- HYBRID drive mode: the combustion engine is active all the time or too often
Was der Fehler beeinflussen kann1
- The high voltage battery cannot be charged by the combustion engine
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.