OBC-P0D2017
VOLVO
OBC-P0D2017 - Battery Charger Output Voltage Performance. General Electrical Failures. Circuit voltage above threshold
System
Bordladegerät (OBC)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
1 ModellV60 (2011–)
Modelle nach Baujahr und Motor anzeigen (2)
Was bedeutet der Fehlercode?
The battery charger control module (OBC) checks the output voltage once charging has started through the charging cable. The code is set when the voltage is too high, and the fault may lie in a defective charging cable or in the battery charger itself.
Mögliche Ursachen
- The charging cable is defective
- Internal fault in the battery charger control module (OBC)
Was Sie tun können
- 1Look at the charging cable for breaks, damage and chafing
- 2If you have another compatible charging cable, try it and see whether the fault remains
- 3If the cable is intact and the fault remains, have a workshop check the battery charger
- 4Do not work on the battery charger or its connections yourself; it is part of the high-voltage section and a job for a workshop
Symptome, die Sie bemerken können2
- Charging of the high voltage battery from an external cable does not work
- The lamp in the charging socket signals a fault or reduced charging
Was der Fehler beeinflussen kann1
- No charging of the high voltage battery can take place