OBC-P0D2400
VOLVO
OBC-P0D2400 - Battery Charger Temperature Too High. General Failure Information. No sub type information
System
Bordladegerät (OBC)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
1 ModellV60 (2011–)
Modelle nach Baujahr und Motor anzeigen (2)
Was bedeutet der Fehlercode?
The battery charger's internal temperature is measured by two sensors built into it. When the temperature is too high, charging from an external cable becomes weaker or is blocked altogether. The code is set when the control module detects raised temperature.
Mögliche Ursachen
- The charger has overheated
- Fault in the cooling system for the high voltage system
- Too little refrigerant in the cooling system
- Ambient temperature too high
Was Sie tun können
- 1Check the coolant level in the cooling system for the high voltage system while the system is cold
- 2Look for coolant leaks on the cooling system for the high voltage system
- 3Let the car and the charger cool down before trying to charge again
- 4Have a workshop trace any leak and check the refrigerant charge
- 5Do not work on the high-voltage cooling circuits yourself; that is a job for a workshop
Symptome, die Sie bemerken können2
- Charging from an external cable does not work or works poorly
- The lamp in the charging socket signals a fault or reduced charging
Was der Fehler beeinflussen kann1
- Charging from outside is blocked for the high voltage battery
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.