OBC-P0D9815
VOLVO
OBC-P0D9815 - Battery Charger Coupler Unlock Control Circuit Performance. General Electrical Failures. Circuit short to battery or open
System
Bordladegerät (OBC)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
1 ModellV60 (2011–)
Modelle nach Baujahr und Motor anzeigen (2)
Was bedeutet der Fehlercode?
The battery charger control module (OBC) checks that the cable can be latched to the car by the lock motor inside the charging socket. The fault is set when the activation signal to the lock motor is overloaded. Charging the high voltage battery is not possible while the fault remains.
Mögliche Ursachen
- Overload on the signal to the lock motor
Was Sie tun können
- 1Read out and erase the fault code, charge again and see whether it comes back
- 2Check that the charging socket in the car is not damaged and that the charging cable can be locked into it without anything blocking it
- 3Have a workshop check the cables to the charging socket. Do not work on the high voltage system yourself
Symptome, die Sie bemerken können3
- Charging the high voltage battery from an external charging cable does not happen, is reduced or does not work correctly
- The LED on the charging cable or the charging socket shows a fault and charging is reduced
- The lock function in the charging socket does not lock or unlock the charging cable
Was der Fehler beeinflussen kann1
- Charging the high voltage battery is not possible
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.