OBC-P0D9916
VOLVO
OBC-P0D9916 - Battery Charger Coupler Temperature Sensor Circuit. General Electrical Failures. Circuit voltage below threshold
System
Bordladegerät (OBC)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
1 ModellV60 (2011–)
Modelle nach Baujahr und Motor anzeigen (2)
Was bedeutet der Fehlercode?
The battery charger control module (OBC) checks that the temperature reading from the charging socket is right. The fault is set when the sensor reads too low a signal. The fault can come from a damaged sensor in the charging socket or from damage to gateway OBC or its connection, and then charging the high voltage battery is not possible.
Mögliche Ursachen
- The sensor reading the charging socket temperature is damaged
- Defective connection to gateway OBC
- Gateway OBC is damaged
Was Sie tun können
- 1Read out and erase the fault code, charge again and see whether it comes back
- 2Have a workshop check that the charging socket in the car is not damaged and that the cable is fully seated in it
- 3Have a workshop check the cables and gateway OBC. Do not work on the high voltage system yourself
Symptome, die Sie bemerken können2
- Charging the high voltage battery from an external charging cable does not happen, is reduced or does not work correctly
- The LED on the charging cable or the charging socket shows a fault and charging is reduced
Was der Fehler beeinflussen kann1
- Charging the high voltage battery is not possible
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.