OBC-U300317
VOLVO
OBC-U300317 - Battery Voltage. General Electrical Failures. Circuit voltage above threshold
System
Bordladegerät (OBC)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
1 ModellV60 (2011–)
Modelle nach Baujahr und Motor anzeigen (2)
Was bedeutet der Fehlercode?
The battery charger control module (OBC) checks the voltage it runs on itself. The fault is set when an incorrect value lasts for a while. The fault can be caused by a short circuit to supply voltage on the cable, which makes the voltage too high. Charging the high voltage battery is not possible while the fault remains.
Mögliche Ursachen
- Short circuit to supply voltage on the cable
Was Sie tun können
- 1Have a workshop check that the fuses in the car are intact and that the battery cables are firmly attached
- 2Read out and erase the fault code, charge again and see whether it comes back
- 3Have a workshop check the supply cable for a short circuit to supply voltage. Do not work on the high voltage system yourself
Symptome, die Sie bemerken können3
- Charging the high voltage battery from an external charging cable does not happen, is reduced or does not work correctly
- The LED on the charging cable or the charging socket shows a fault and charging is reduced
- A text message and a warning symbol are shown in the display
Was der Fehler beeinflussen kann1
- Charging the high voltage battery is not possible
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.