PHM-0211
VOLVO
PHM-0211 - Internal Backup speaker Signal too low
System
Telefonmodul (PHM)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
4 ModelleC30 (2007–2013), C70 (2006–2013), S40 (2004–2013), V50 (2004–2013)
Modelle nach Baujahr und Motor anzeigen (4)
Was bedeutet der Fehlercode?
The carphone control module (PHM) monitors the voltage on the spare loudspeaker, and the code is set when the voltage is too low. The reason is that the spare loudspeaker is short-circuited to ground. Volvo On Call can then work poorly, the telephone may have other problems, and a warning symbol appears.
Mögliche Ursachen
- The spare loudspeaker is short-circuited to ground
Was Sie tun können
- 1Read and note the code before clearing it, so the workshop can see it
- 2Have a workshop with diagnostic equipment check the spare loudspeaker for a short to ground
- 3If the fault remains, have a workshop replace the carphone control module (PHM)
Symptome, die Sie bemerken können3
- Other mobile phone problems
- Other Volvo On Call problems
- A text message appears together with a warning symbol
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.