PSL-0047
VOLVO
PSL-0047 - Hall sensor ground backrest. Short to supply
System
Antriebsstrang (Motor & Getriebe)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
3 ModelleC30 (2007–2013), C30 Electric (2011–2013), C70 (2006–2013)
Modelle nach Baujahr und Motor anzeigen (3)
Was bedeutet der Fehlercode?
The left front seat module (PSL) registers too high a reading from the Hall sensor in the backrest, and the fault code is set then. The fault lies in the earth wire, which has contact with supply voltage.
Mögliche Ursachen
- The earth wire is shorted to supply voltage
Was Sie tun können
- 1Read and note the fault code, clear it and run the backrest to see whether it returns
- 2Use a multimeter to check that the earth wire to the backrest Hall sensor has no contact with supply voltage
- 3Check the connector at the backrest Hall sensor: it should be secure and free from oxidation
- 4If no fault is found in the connector or wire, have a workshop replace the Hall sensor or the control module and then initialise the seat
- 5After the work, check that the seat can move the same distance forwards whether the backrest is folded down or upright
Symptome, die Sie bemerken können1
- Seat functions work worse than normal
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.