PSR-0007
VOLVO
PSR-0007 - M1, M2, M3, M4 or MC. Shorted to supply
System
Antriebsstrang (Motor & Getriebe)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
3 ModelleC30 (2007–2013), C30 Electric (2011–2013), C70 (2006–2013)
Modelle nach Baujahr und Motor anzeigen (3)
Was bedeutet der Fehlercode?
The right power seat control module (PSR) registers too high a voltage on one of the signal wires to the seat motors. This means that wire is touching a live supply instead of being insulated, and the automatic adjustments can stop working as a result.
Mögliche Ursachen
- One of the signal wires to the seat motors is shorted to voltage
Was Sie tun können
- 1With the battery negative lead disconnected, use a multimeter to check that the signal wires to the seat motors are not in contact with voltage
- 2Look for chafing, pinched areas or melted insulation on the wires to the seat motors and repair them
- 3Check that the connectors to the seat motors are firmly fitted and undamaged
- 4If the wires are intact, have a workshop check the seat motors and the seat control module
Symptome, die Sie bemerken können1
- Automatic adjustment of the seat and outer mirror does not work
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.