PSR-0047
VOLVO
PSR-0047 - Hall sensor ground backrest. Short to supply
System
Antriebsstrang (Motor & Getriebe)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
3 ModelleC30 (2007–2013), C30 Electric (2011–2013), C70 (2006–2013)
Modelle nach Baujahr und Motor anzeigen (3)
Was bedeutet der Fehlercode?
The right power seat control module (PSR) monitors the backrest hall sensor and finds its signal too high. The fault lies in the ground wire being shorted to voltage, and backrest adjustment is reduced as a result.
Mögliche Ursachen
- Short to voltage in the ground wire to the backrest hall sensor
Was Sie tun können
- 1Check that the seat fuses are intact; their locations are in the owner's manual or on the fuse chart
- 2Check the backrest hall sensor connector for poor contact, oxidation and loose joints
- 3With the battery negative lead disconnected, use a multimeter to check that the hall sensor ground wire has no contact with voltage
- 4If the wiring is intact but the fault remains, have a workshop replace the hall sensor and, if the fault still remains, the control module
- 5Clear the code after the work and check that the backrest adjusts as normal
Symptome, die Sie bemerken können1
- Reduced seat function
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.