PSR-004A
VOLVO
PSR-004A - Hall sensor backrest. Open circuit
System
Antriebsstrang (Motor & Getriebe)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
3 ModelleC30 (2007–2013), C30 Electric (2011–2013), C70 (2006–2013)
Modelle nach Baujahr und Motor anzeigen (3)
Was bedeutet der Fehlercode?
The right power seat control module (PSR) checks the signal from the backrest hall sensor and registers a signal that is too low. This can come from an open circuit in the cable or from the cable being shorted to ground, and backrest adjustment is reduced as a result.
Mögliche Ursachen
- Open circuit in the cable to the backrest hall sensor
- Short to ground in the cable
Was Sie tun können
- 1Check that the seat fuses are intact; their locations are in the owner's manual or on the fuse chart
- 2With the battery negative lead disconnected, use a multimeter to check that the cable to the hall sensor has no open circuit
- 3Use a multimeter to check that the cable has no contact with ground (the bodywork)
- 4Check the connectors in the cable for loose or oxidised joints
- 5If the wiring is intact but the fault remains, have a workshop replace the hall sensor and, if the fault still remains, the control module
Symptome, die Sie bemerken können1
- Reduced seat function
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.