CPM-B1D2612
VOLVO
CPM-B1D2612 - Combustion Air Blower. General Electrical Failures. Circuit short to battery
System
Verbrennungsheizung (CPM)
Volvo-Modelle, für die dieser Fehlercode gilt
Gilt für folgende Modelle:
2 ModelleV40 (2013–), V40 Cross Country (2013–)
Modelle nach Baujahr und Motor anzeigen (2)
Was bedeutet der Fehlercode?
The heater control module has registered too high a signal on the cable to the combustion fan, which points to a short to battery voltage. The heater cannot be started until the fault code has been erased.
Mögliche Ursachen
- The cable between the heater control module and the combustion fan is short-circuited to battery voltage
Was Sie tun können
- 1With the ignition off, check the cable from the heater to the fan and the connectors for chafing, damage and corrosion.
- 2With the ignition off, use a multimeter: voltage on the fan cable means a short to positive.
- 3Check that the fan wheel is not jammed or stuck and that it turns without resistance.
- 4If you have a diagnostic tool: activate the heater fan and listen for a buzzing sound. If nothing is heard, the fault is probably still present.
- 5Replace the fan motor if it is damaged, or have a workshop do it.
- 6If the fault remains after checking the wiring, have a workshop check the heater control module.
Symptome, die Sie bemerken können1
- The parking heater does not work
Was der Fehler beeinflussen kann1
- The heater cannot be started until the fault code has been erased
Allgemeine Hinweise für Fahrzeughalter. Die Diagnose am Fahrzeug kann eine andere Ursache zeigen.