Verbrennungsheizung (CPM)
Volvo V40 Cross Country (2013–) – Fehlercodes Verbrennungsheizung (CPM)
42 Fehlercodes
Derselbe Fehlercode kann je nach Modelljahr und Motor unterschiedliche Bedeutungen haben. Jede Bedeutung steht deshalb in einer eigenen Zeile, mit genau den Fahrzeugen, für die sie gilt.
Die Fehlercodebeschreibungen liegen auf Schwedisch und Englisch vor und werden hier auf Englisch angezeigt.
| Code | Bedeutung |
|---|---|
| CPM-B102A11 | Flame Sensor. General Electrical Failures. Circuit short to ground2013–2015 |
| CPM-B102A15 | Flame Sensor. General Electrical Failures. Circuit short to battery or open2013–2015 |
| CPM-B120668 | Crash Occured. Algorithm Based Failures. Event information2013–2015 |
| CPM-B1D2211 | Coolant Temperature Sensor. General Electrical Failures. Circuit short to ground2013–2015 |
| CPM-B1D2215 | Coolant Temperature Sensor. General Electrical Failures. Circuit short to battery or open2013–2015 |
| CPM-B1D2311 | Overheat Sensor. General Electrical Failures. Circuit short to ground2013–2015 |
| CPM-B1D2315 | Overheat Sensor. General Electrical Failures. Circuit short to battery or open2013–2015 |
| CPM-B1D2385 | Overheat Sensor. Bus Signal / Message Failures. Signal above allowable range2013–2015 |
| CPM-B1D2386 | Overheat Sensor. Bus Signal / Message Failures. Signal invalid2013–2015 |
| CPM-B1D2411 | Glow Plug. General Electrical Failures. Circuit short to ground2013–2015 |
| CPM-B1D2412 | Glow Plug. General Electrical Failures. Circuit short to battery2013–2015 |
| CPM-B1D2413 | Glow Plug. General Electrical Failures. Circuit open2013–2015 |
| CPM-B1D2511 | Heater Fuel Pump. General Electrical Failures. Circuit short to ground2013–2015 |
| CPM-B1D2512 | Heater Fuel Pump. General Electrical Failures. Circuit short to battery2013–2015 |
| CPM-B1D2513 | Heater Fuel Pump. General Electrical Failures. Circuit open2013–2015 |
| CPM-B1D2611 | Combustion Air Blower. General Electrical Failures. Circuit short to ground2013–2015 |
| CPM-B1D2612 | Combustion Air Blower. General Electrical Failures. Circuit short to battery2013–2015 |
| CPM-B1D2613 | Combustion Air Blower. General Electrical Failures. Circuit open2013–2015 |
| CPM-B1D2671 | Combustion Air Blower. Mechanical Failures. Actuator stuck2013–2015 |
| CPM-B1D2711 | Heater Coolant Pump. General Electrical Failures. Circuit short to ground2013–2015 |
| CPM-B1D2712 | Heater Coolant Pump. General Electrical Failures. Circuit short to battery2013–2015 |
| CPM-B1D2713 | Heater Coolant Pump. General Electrical Failures. Circuit open2013–2015 |
| CPM-B1D2993 | No start, even after restart attempt. Component Failures. No operation2013–2015 |
| CPM-B1D3194 | Flame detected prior to normal operation. Component Failures. Unexpected operation2013–2015 |
| CPM-B1D3292 | Multiple flame interruption during heating cycle. Component Failures. Performance or incorrect operation2013–2015 |
| CPM-B1D3466 | Heater in lock out mode. Algorithm Based Failures. Signal has too many transitions / events2013–2015 |
| CPM-P014862 | Fuel Delivery Error. Algorithm Based Failures. Signal compare failure2013–2015 |
| CPM-U001088 | Medium Speed CAN Communication Bus. Bus Signal / Message Failures. Bus off2013–2015 |
| CPM-U014000 | Lost communication with Central Electronic Module (CEM). General Failure Information. No sub type information2013–2015 |
| CPM-U030000 | Internal Control Module Software Incompatibility. General Failure Information. No sub type information2013–2015 |
| CPM-U201694 | Control Module Main Software. Component Failures. Unexpected operation2013–2015 |
| CPM-U210000 | Initial Configuration Not Complete. General Failure Information. No sub type information2013–2015 |
| CPM-U210100 | Control Module Configuration Incompatible. General Failure Information. No sub type information2013–2015 |
| CPM-U300044 | Control Module. System Internal Failures. Data memory failure2013–2015 |
| CPM-U300045 | Control Module. System Internal Failures. Program memory failure2013–2015 |
| CPM-U300046 | Control Module. System Internal Failures. Calibration / parameter memory failure2013–2015 |
| CPM-U300047 | Control Module. System Internal Failures. Watchdog / safety µC failure2013–2015 |
| CPM-U300048 | Control Module. System Internal Failures. Supervision software failure2013–2015 |
| CPM-U300049 | Control Module. System Internal Failures. Internal electronic failure2013–2015 |
| CPM-U300316 | Battery Voltage. General Electrical Failures. Circuit voltage below threshold2013–2015 |
| CPM-U300317 | Battery Voltage. General Electrical Failures. Circuit voltage above threshold2013–2015 |
| CPM-U300362 | Battery Voltage. Algorithm Based Failures. Signal compare failure2013–2015 |