CEM-1A10
VOLVO
CEM-1A10 - Secondary battery Signal to low
Układ
Centralny moduł elektroniczny (CEM)
Modele Volvo, których dotyczy ten kod błędu
Dotyczy następujących modeli:
4 modeleC30 (2007–2013), C70 (2006–2013), S40 (2004–2013), V50 (2004–2013)
Pokaż modele wg rocznika i silnika (4)
Co oznacza ten kod błędu?
This fault only applies to cars with automatic engine start and stop. The CEM monitors the secondary battery voltage. If the voltage is too low or too high, the automatic start and stop function does not work.
Możliwe przyczyny
- Contact resistance or oxidation in the terminals
- Damaged fuse for the voltage supply
- Open circuit on the voltage supply from the secondary battery, or on its ground cable
- Poorly charged battery or corroded connecting cables
- Damaged battery
- A battery charger with the wrong voltage has been used
Co możesz zrobić
- 1Check that the battery is charged and that the battery terminals are clean and tight
- 2Check the fuse for the voltage supply from the secondary battery
- 3Has a battery charger been used recently? Check that it is meant for this car
- 4Clear the code and road test the car to see whether it returns
- 5If the fault remains, have a workshop check the secondary battery
Objawy, które możesz zauważyć2
- Automatic engine start and stop does not work
- Idling with automatic engine start and stop does not work
Ogólne wskazówki dla właścicieli. Diagnostyka na samochodzie może wskazać inną przyczynę.