CPM-B1D2315
VOLVO
CPM-B1D2315 - Overheat Sensor. General Electrical Failures. Circuit short to battery or open
Układ
Ogrzewanie postojowe (CPM)
Modele Volvo, których dotyczy ten kod błędu
Dotyczy następujących modeli:
2 modeleV40 (2013–), V40 Cross Country (2013–)
Pokaż modele wg rocznika i silnika (2)
Co oznacza ten kod błędu?
The combustion preheater module (CPM) has registered a signal from the overheat protection thermostat that is too high. The cause may be a short to supply voltage in the cable, a break, a damaged thermostat or poor contact. The heater cannot be activated until the fault code has been cleared.
Możliwe przyczyny
- The cable between the CPM and the overheat protection thermostat is shorted to supply voltage
- Break in the cable between the CPM and the overheat protection thermostat
- Damaged overheat protection thermostat
- Contact resistance, oxidation or loose connections
Co możesz zrobić
- 1Clear the code and check whether it returns when the ignition is switched on
- 2Disconnect the connector at the overheat protection thermostat and check that the contacts are secure and free from oxidation
- 3Use a multimeter to check that the cable carries no voltage when the heater is off; if it does, the cable is shorted to positive
- 4Use a multimeter to check the cable is intact between the heater connector and the thermostat connector; a break means the cable must be replaced
- 5If the fault returns, have a workshop measure the thermostat resistance
Objawy, które możesz zauważyć1
- The parking heater does not work
Na co może wpływać usterka1
- The heater cannot be activated until the fault code has been cleared
Ogólne wskazówki dla właścicieli. Diagnostyka na samochodzie może wskazać inną przyczynę.