CPM-B1D2712 - Heater Coolant Pump. General Electrical Failures. Circuit short to battery
Układ
Ogrzewanie postojowe (CPM)
Modele Volvo, których dotyczy ten kod błędu
Dotyczy następujących modeli:
2 modeleV40 (2013–), V40 Cross Country (2013–)
Pokaż modele wg rocznika i silnika (2)
Co oznacza ten kod błędu?
The heater control module has registered too high a signal on the cable to the coolant pump. This points to a short to battery voltage or to a damaged pump. The heater cannot be started until the fault code has been erased.
Możliwe przyczyny
- The cable between the heater control module and the coolant pump is short-circuited to battery voltage
- Damaged coolant pump
Co możesz zrobić
- 1With the ignition off, check the cable and connectors to the coolant pump for chafing, damage and corrosion.
- 2With the ignition off, use a multimeter: voltage on the pump cable means a short to positive.
- 3If you have a diagnostic tool: activate the water pump and listen for a buzzing sound. If it does not start, the fault is still present.
- 4Replace the coolant pump if it is damaged, or have a workshop do it.
- 5If the wiring is in good condition, have a workshop check the pump and the heater control module.
Objawy, które możesz zauważyć1
- The parking heater does not work
Na co może wpływać usterka1
- The heater cannot be started until the fault code has been erased
Ogólne wskazówki dla właścicieli. Diagnostyka na samochodzie może wskazać inną przyczynę.