ECM-258C
VOLVO
ECM-258C - Front heated oxygen sensor (HO2S), bank 2. Signal too high
Układ
Sterownik silnika (ECM)
Modele Volvo, których dotyczy ten kod błędu
Dotyczy następujących modeli:
2 modeleS80 (1999–2006), XC90 (2003–)
Pokaż modele wg rocznika i silnika (2)
Co oznacza ten kod błędu?
The engine control module (ECM) detects that the signal wires to the oxygen sensor on bank 2 are shorted to supply voltage. Although the fault shows as a signal that is too high, the cause lies in the wiring or the sensor.
Możliwe przyczyny
- Signal wires shorted to supply voltage
- Damaged oxygen sensor on bank 2
Co możesz zrobić
- 1Read the code, clear it and road test the car to see whether it returns
- 2Check that the connector at the lambda sensor is fully engaged and clean. No rust solvent spray or grease in the connector
- 3With the control module disconnected, use a multimeter to check that the signal wires have no contact with supply voltage
- 4Look for chafed spots on the wires where they may have touched a live wire or been pinched
- 5If the wiring is intact the sensor may be damaged; have a workshop check or replace it
Objawy, które możesz zauważyć1
- Malfunction indicator lamp (MIL) on
Ogólne wskazówki dla właścicieli. Diagnostyka na samochodzie może wskazać inną przyczynę.