ECM-P051217 - Starter Request Circuit. General Electrical Failures. Circuit voltage above threshold
Układ
Sterownik silnika (ECM)
Modele Volvo, których dotyczy ten kod błędu
Dotyczy następujących modeli:
7 modeliS60 (2011–), S80 (2007–), V40 (2013–), V40 Cross Country (2013–), V60 (2011–), V70 (2008–), XC60 (2009–)
Pokaż modele wg rocznika i silnika (20)
- Volvo S60 (2011–)2011Tylko silnik: B4164T, B4164T3, B4204T6, B4204T7
- Volvo S60 (2011–)2012–2014Tylko silnik: B4164T, B4164T2, B4164T3, B4204T7
- Volvo S60 (2011–)2015Tylko silnik: B4164T, B4164T2, B4164T3
- Volvo S80 (2007–)2010Tylko silnik: B4204T6
- Volvo S80 (2007–)2011Tylko silnik: B4164T, B4204T6, B4204T7
- Volvo S80 (2007–)2012–2014Tylko silnik: B4164T, B4164T2, B4204T6, B4204T7
- Volvo S80 (2007–)2015Tylko silnik: B4164T
- Volvo V40 (2013–)2013Tylko silnik: B4164T, B4164T3
- Volvo V40 (2013–)2014–2015Tylko silnik: B4164T, B4164T3, B4164T4
- Volvo V40 Cross Country (2013–)2013–2015Tylko silnik: B4164T
- Volvo V60 (2011–)2011Tylko silnik: B4164T, B4164T3, B4204T6, B4204T7
- Volvo V60 (2011–)2012–2014Tylko silnik: B4164T, B4164T2, B4164T3, B4204T7
- Volvo V60 (2011–)2015Tylko silnik: B4164T, B4164T2, B4164T3
- Volvo V70 (2008–)2010Tylko silnik: B4204T6
- Volvo V70 (2008–)2011Tylko silnik: B4164T, B4204T6, B4204T7
- Volvo V70 (2008–)2012–2014Tylko silnik: B4164T, B4164T2, B4204T7
- Volvo V70 (2008–)2015Tylko silnik: B4164T, B4164T2
- Volvo XC60 (2009–)2010Tylko silnik: B4204T6
- Volvo XC60 (2009–)2011–2012Tylko silnik: B4204T6, B4204T7
- Volvo XC60 (2009–)2013–2015Tylko silnik: B4204T7
Co oznacza ten kod błędu?
When the engine is started, the ECM sends a signal to the starter relay. The code is set when the module finds that the voltage in the circuit is too high, which means the signal controlling the starter motor through the relay is faulty. The fault may be a signal wire shorted to supply voltage, poor connections, or an internal fault in the module.
Możliwe przyczyny
- Signal wire shorted to supply voltage
- Contact resistance, oxidation or break in connections
- Internal fault in the ECM
Co możesz zrobić
- 1Check that the fuses are intact
- 2Check the signal wire between the engine control module and the starter relay for chafing and places where it may have touched a voltage source
- 3Use a multimeter to check that the signal wire has no contact with voltage when the ignition is off
- 4Check the connectors in the signal circuit for oxidation and loose connections
- 5If you have a diagnostic tool, read the relevant start signals in live data during starting attempts
- 6If the fault returns, have a workshop with diagnostic equipment check the engine control module
Objawy, które możesz zauważyć1
- No noticeable symptoms for the driver