ECM-P05621C
VOLVO
ECM-P05621C - System Voltage Low. General Electrical Failures. Circuit voltage out of range
Układ
Sterownik silnika (ECM)
Modele Volvo, których dotyczy ten kod błędu
Dotyczy następujących modeli:
7 modeliS60 (2011–), S80 (2007–), V40 (2013–), V40 Cross Country (2013–), V60 (2011–), V70 (2008–), XC60 (2009–)
Pokaż modele wg rocznika i silnika (20)
- Volvo S60 (2011–)2011Tylko silnik: B4164T, B4164T3, B4204T6, B4204T7
- Volvo S60 (2011–)2012–2014Tylko silnik: B4164T, B4164T2, B4164T3, B4204T7
- Volvo S60 (2011–)2015Tylko silnik: B4164T, B4164T2, B4164T3
- Volvo S80 (2007–)2010Tylko silnik: B4204T6
- Volvo S80 (2007–)2011Tylko silnik: B4164T, B4204T6, B4204T7
- Volvo S80 (2007–)2012–2014Tylko silnik: B4164T, B4164T2, B4204T6, B4204T7
- Volvo S80 (2007–)2015Tylko silnik: B4164T
- Volvo V40 (2013–)2013Tylko silnik: B4164T, B4164T3
- Volvo V40 (2013–)2014–2015Tylko silnik: B4164T, B4164T3, B4164T4
- Volvo V40 Cross Country (2013–)2013–2015Tylko silnik: B4164T
- Volvo V60 (2011–)2011Tylko silnik: B4164T, B4164T3, B4204T6, B4204T7
- Volvo V60 (2011–)2012–2014Tylko silnik: B4164T, B4164T2, B4164T3, B4204T7
- Volvo V60 (2011–)2015Tylko silnik: B4164T, B4164T2, B4164T3
- Volvo V70 (2008–)2010Tylko silnik: B4204T6
- Volvo V70 (2008–)2011Tylko silnik: B4164T, B4204T6, B4204T7
- Volvo V70 (2008–)2012–2014Tylko silnik: B4164T, B4164T2, B4204T7
- Volvo V70 (2008–)2015Tylko silnik: B4164T, B4164T2
- Volvo XC60 (2009–)2010Tylko silnik: B4204T6
- Volvo XC60 (2009–)2011–2012Tylko silnik: B4204T6, B4204T7
- Volvo XC60 (2009–)2013–2015Tylko silnik: B4204T7
Co oznacza ten kod błędu?
The ECM monitors the system voltage and sets the code when the voltage is wrongly low. The causes can lie in the generator, the charging system or the battery, but also in contact resistance in connectors and connections.
Możliwe przyczyny
- Problem with the generator
- Faulty charging system
- Damaged battery
- Contact resistance or oxidation in connectors and connections
Co możesz zrobić
- 1Check that the fuses are intact
- 2Check the battery terminals and connections for contact resistance and oxidation
- 3Check the other connectors and connections in the charging circuit for looseness and oxidation
- 4If you have diagnostic equipment: read the system voltage in live data with the engine running and compare it with the value when the engine is stopped
- 5If the connections are clean and tight, have a workshop check the generator and battery
Objawy, które możesz zauważyć2
- The engine is hard to start and the starter motor cranks slowly, hard to tell when it happens
- The engine does not start, hard to tell when it happens
Ogólne wskazówki dla właścicieli. Diagnostyka na samochodzie może wskazać inną przyczynę.