ECM-P056317
VOLVO
ECM-P056317 - System Voltage High. General Failure Information. No sub type information
Układ
Sterownik silnika (ECM)
Modele Volvo, których dotyczy ten kod błędu
Dotyczy następujących modeli:
7 modeliS60 (2011–), S80 (2007–), V40 (2013–), V40 Cross Country (2013–), V60 (2011–), V70 (2008–), XC60 (2009–)
Pokaż modele wg rocznika i silnika (20)
- Volvo S60 (2011–)2011Tylko silnik: B4164T, B4164T3, B4204T6, B4204T7
- Volvo S60 (2011–)2012–2014Tylko silnik: B4164T, B4164T2, B4164T3, B4204T7
- Volvo S60 (2011–)2015Tylko silnik: B4164T, B4164T2, B4164T3
- Volvo S80 (2007–)2010Tylko silnik: B4204T6
- Volvo S80 (2007–)2011Tylko silnik: B4164T, B4204T6, B4204T7
- Volvo S80 (2007–)2012–2014Tylko silnik: B4164T, B4164T2, B4204T6, B4204T7
- Volvo S80 (2007–)2015Tylko silnik: B4164T
- Volvo V40 (2013–)2013Tylko silnik: B4164T, B4164T3
- Volvo V40 (2013–)2014–2015Tylko silnik: B4164T, B4164T3, B4164T4
- Volvo V40 Cross Country (2013–)2013–2015Tylko silnik: B4164T
- Volvo V60 (2011–)2011Tylko silnik: B4164T, B4164T3, B4204T6, B4204T7
- Volvo V60 (2011–)2012–2014Tylko silnik: B4164T, B4164T2, B4164T3, B4204T7
- Volvo V60 (2011–)2015Tylko silnik: B4164T, B4164T2, B4164T3
- Volvo V70 (2008–)2010Tylko silnik: B4204T6
- Volvo V70 (2008–)2011Tylko silnik: B4164T, B4204T6, B4204T7
- Volvo V70 (2008–)2012–2014Tylko silnik: B4164T, B4164T2, B4204T7
- Volvo V70 (2008–)2015Tylko silnik: B4164T, B4164T2
- Volvo XC60 (2009–)2010Tylko silnik: B4204T6
- Volvo XC60 (2009–)2011–2012Tylko silnik: B4204T6, B4204T7
- Volvo XC60 (2009–)2013–2015Tylko silnik: B4204T7
Co oznacza ten kod błędu?
The ECM checks the voltage supply from the system relay. The fault is stored when the reading from the system relay exceeds a set value. The cause may be a faulty charging system.
Możliwe przyczyny
- Faulty charging system
Co możesz zrobić
- 1Check that the fuses are intact
- 2If a battery charger has been connected recently, it may have supplied too high a charging voltage and caused this code
- 3If you have diagnostic equipment: read the system voltage in live data with the engine running and compare it with the battery voltage, which you can measure with a multimeter
- 4Switch on some high-consumption functions such as the cabin fan and headlights and check whether the voltage follows
- 5Have a workshop check the generator brushes and slip rings and replace the generator control module (ACM) or the generator if needed
Objawy, które możesz zauważyć1
- No noticeable symptoms for the driver
Ogólne wskazówki dla właścicieli. Diagnostyka na samochodzie może wskazać inną przyczynę.