ECM-P30034B
VOLVO
ECM-P30034B - A/C Shut Off Valve. System Internal Failures. Over temperature
Układ
Sterownik silnika (ECM)
Modele Volvo, których dotyczy ten kod błędu
Dotyczy następujących modeli:
1 modelV60 (2011–)
Pokaż modele wg rocznika i silnika (2)
Co oznacza ten kod błędu?
Even though the code is named over temperature, it concerns the signal wire to the A/C shut-off valve, which the engine control module (ECM) monitors. The code is set when the signal wire is shorted or has an open circuit, and then the air conditioning is affected.
Możliwe przyczyny
- Mechanical fault on the valve
- Electrical fault on the valve
- Short circuit or open circuit in the wires to the valve
Co możesz zrobić
- 1Read the code with a diagnostic tool and see whether it is active or only stored
- 2Check that the connectors to the valve are secure and free from oxidation
- 3Use a multimeter to check that the wires to the valve have no break and no contact with ground (the body)
- 4Have a workshop check the valve if the fault remains
Objawy, które możesz zauważyć3
- Temperature control or air conditioning does not work
- The combustion engine runs in HYBRID mode more often than expected
- Warning symbol and text message in the display
Ogólne wskazówki dla właścicieli. Diagnostyka na samochodzie może wskazać inną przyczynę.