ECM-P30044B
VOLVO
ECM-P30044B - Power Sustain Relay. System Internal Failures. Over temperature
Układ
Sterownik silnika (ECM)
Modele Volvo, których dotyczy ten kod błędu
Dotyczy następujących modeli:
1 modelV60 (2011–)
Pokaż modele wg rocznika i silnika (2)
Co oznacza ten kod błędu?
Even though the code is named over temperature, it concerns the signal wire to the voltage supply relay, which the engine control module (ECM) monitors. The code is set when the signal wire is shorted or has an open circuit, and then voltage cannot be connected to the high voltage battery's contactors.
Możliwe przyczyny
- Mechanical fault on the relay
- Electrical fault on the relay
- Short circuit or open circuit in the wires to the relay
Co możesz zrobić
- 1Check that the fuses are intact; their location is shown in the owner's manual
- 2Read the code with a diagnostic tool and check whether it is active or only stored
- 3Have a workshop check the relay and its wiring, since the high voltage system should only be handled by trained personnel
Objawy, które możesz zauważyć3
- The combustion engine runs in HYBRID mode more often than expected
- Temperature control or air conditioning does not work
- Warning symbol and text message in the display
Ogólne wskazówki dla właścicieli. Diagnostyka na samochodzie może wskazać inną przyczynę.